Commercial / Multi-Res Alteration · BP128771
Commercial Alteration, Unit 101 (Eye Plus Optometry) Change of use for new 231.79 m2 CRU from Group E to Group D. Work includes adding exam/treatment rooms,1 unisex w/c,1 universal w/c, staff lounge and retail area.adding 17 sprinkler heads Building Re-Classification: 22 strata unit residential apartment building with 5 commercial rental units on main floor and basement level. 794 m2, 4 storey, Group C 3.2.2.51, Group E 3.2.2.65, Group D 3.2.2.59 & Parking Garage Group F2 3.2.2.75. Total area of all floors, including parking garage is 3634.4 m2. Sprinklered, Fire Alarm system, combustible and/or noncombustible construction. 1 hr. FS/F.R.R. is required between suites, suites and corridors/stairwells/elevator shaft and 1 hr. F.R.R. for floor assemblies, load-bearing walls and columns. Parking Garage is required to be separated from the remainder of the building by a 1.5 hrs. FS/F.R.R.
Other addresses listed in this application: 101 525 THIRD STREET; 525 THIRD STREET.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.