Commercial / Multi-Res Alteration · BP129281
Bldg Env upgrade and int. renos to apartment building. Work includes; replacement of plumbing fixtures within suites, and emergency/exit lighting; and upgrades to mechanical/fire alarm systems. Permit includes the new installation of 7 HWTs in basement, and NFPA13/14 sprinkler/standpipe system by bylaw. New interior finishes in suites (floors/bathroom ceilings) and corridors (floors/ceilings). Existing FS/FRR to be maintained. Exist Bldg classification; Exist NBC 1970 Part 3, 3.2.2.27 Group C, 5 storey w/ service basement, ~1005m2 bldg area, unsprinklered (except basement/standpipes/hoses) w/ fire alarm system. 75 residential suites, 1 office, 1 common solarium. Key FS/FRR include; 2hr FS/FRR flr over basement, 1hr FS/FRR for other flrs, btwn suites, and public corridors, 1hr FRR for supporting structures/balconies/roof, 3/4hr FS/FRR for vertical service spaces. REV 25-JAN-10: See internal notes REV 25-JUN-05: See internal notes REV 25-OCT-31: See internal notes