Commercial / Multi-Res Alteration · BP128365
Permit for Change of Use from D/F2 to C/D building, and to resolve CIB05343 for non permitted construction on lower floor. Create new Group C dwelling unit (Unit 202) on upper floor with additional 23.1 m2 GFA, two new Group D CRUs (Units 102, 103) in basement including increased ceiling height and finish previous crawlspace storage area. BCBC 2018 accessible washrooms for new CRUs. Building structure revised to comply with BCBC 2018 Part 9 braced wall band provisions. Building Reclassification: BCBC 2018 Part 9 Group C/D, 184.1 m2 building area, two storeys, combustible and noncombustible construction, unsprinklered, without fire alarm. 45-min FRR/FS floors, 1-hr FRR/FS between Group C/D occupancies, 45-min FRR/FS (none req'd) between Group D suites. 1-hr FRR/FS service room. 50 STC assemblies separating dwelling unit. Single exits permitted for each CRU, max 10 occupants based on BCBC 3.7. REVISION: 2025-JAN-28: Layout change to Unit 103, 102, 202. Braced wall panel revision.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.