Source: City of Nanaimo — Planning, building, demolition and subdivision records
2 storey addition 154.48m2 GFA for warehouse and office space to existing Part 9 Group D office building (Denmar Electric). Scope of work includes new lower floor warehouse space and upper floor offices, new opening in existing upper floor wall, replacing shower with toilet and adding partition walls in existing washroom, Sprinkler heads being installed in attic space. 3/4-hr FRR F/S required exit stairs and floor assemblies. Total GFA is 401.11 m2. Building Classification: 2 storey Part 9 Group D with subsidiary F3, 200.5 m2 building area, sprinklered with fire alarm system. REVISION 2026-APR-14: Minor changes to sprinkler piping and head layout
2 storey addition 154.48m2 GFA for warehouse and office space to existing Part 9 Group D office building (Denmar Electric). Scope of work includes new lower floor warehouse space and upper floor offices, new opening in existing upper floor wall, replacing shower with toilet and adding partition walls in existing washroom, Sprinkler heads being installed in attic space. 3/4-hr FRR F/S required exit stairs and floor assemblies. Total GFA is 401.11 m2. Building Classification: 2 storey Part 9 Group D with subsidiary F3, 200.5 m2 building area, sprinklered with fire alarm system. REVISION 2026-APR-14: Minor changes to sprinkler piping and head layout
Application address
1810 Fremont Rd (Denmar Electric)
Source-reported status
HOLDBACK
Application submitted
Issued date
Source final date
Source expiry date
Other addresses listed in this application: 1810 FREMONT ROAD.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
These are municipal application records. Their status and dates do not establish current construction progress. Associated addresses do not establish a verified parcel history.
These applications share an address listed by the municipality. They remain separate records; this does not confirm that they are phases of one development.
Public Broadcast · screens & websites
Shows only publicly available records. Private records are excluded, even when you are signed in.
Commercial / Multi / Industrial · BP130804
2 storey addition 154.48m2 GFA for warehouse and office space to existing Part 9 Group D office building (Denmar Electric). Scope of work includes new lower floor warehouse space and upper floor offices, new opening in existing upper floor wall, replacing shower with toilet and adding partition walls in existing washroom, Sprinkler heads being installed in attic space. 3/4-hr FRR F/S required exit stairs and floor assemblies. Total GFA is 401.11 m2. Building Classification: 2 storey Part 9 Group D with subsidiary F3, 200.5 m2 building area, sprinklered with fire alarm system. REVISION 2026-APR-14: Minor changes to sprinkler piping and head layout
Source-reported status: HOLDBACK. Application status does not establish construction activity or completion.
Application date: 2025-04-07.
Permit issue date: 2025-10-31.
Source final date: 2026-07-17.
Source expiry date: 2027-10-31.
Addresses listed by the municipality: 1810 FREMONT ROAD. These are source-listed associations, not a verified parcel history.
Municipal application source
City of Nanaimo, What's Building public application CSV. The City is the data source, not necessarily the project owner. This profile is not managed or endorsed by the City.
Source data licence and terms of use
The municipality lists different civic and associated-property addresses. They are retained as source evidence, not verified parcel equivalence.
HueFlux feedback
Recorded project feedback. These responses do not establish property condition or represent the whole community.
Essential cookies keep FolioProjects working. With your permission, Mouseflow records visits to selected public marketing pages. Recording is disabled when you are signed in and on private pages.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.