Commercial / Multi-Res Alteration · BP128811
Commercial alteration of unit 110 for indoor playground. Change of use from Group E to Group A2, 922m2. Historic equivalent approach to building code compliance required a FS with a 1HR FRR between the suite and the "altered public corridor" FS (shaft wall) with a 2HR FRR now required between suite and adjoining Group E occupancies. Maximum occupant load of 50 including staff, based on health requirements. Building Sprinkled to NFPA 13, BCBC 2018 Governing Articles 3.2.2.24/3.2.2.64/3.2.2.55 Non Combustible construction Adding two sinks, washrooms are unisex, one washroom to be upgraded to meet accessibility requirements 2023-FEB-23 REVISION: Structural Engineer added for over height walls, delete new wall in claw machine area, Existing washroom #1 changed to an accessible washroom, both washrooms changed to be unisex washrooms, add 2 hour F.R.R,. shaft wall system for the fire separation between proposed Group A2 and adjacent retail space Group E.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.