Commercial / Multi-Res Alteration · BP129903
Building permit to resolve CIB06053 Illegal Construction: addition of new 1-hr FRR/FS (45-min FRR/FS required) between Unit 101 (373.5 m2, New-Line Hose and Fittings) and Unit 102 (676.5 m2, Delco Fireplaces), partial removal of mezzanine in Unit 101, new access through loadbearing wall to Unit 102 warehouse bay. Occupant load limited to 10 persons in each suite based on health requirements. Removal of unpermitted storage mezzanines and covered walkways with overhead storage in Unit 102 warehouse areas. Existing Building Classification (CIB06053): NBC 1977 3.2.2.42. Group F2, 1,050 m2 (11,300 sq ft) building area, two storeys, facing one street, combustible construction, unsprinklered, without fire alarm. 45-min FRR/FS floors, 45-min FRR mezzanine/roof/loadbearing assemblies. Equivalent BCBC 2018 classification 3.2.2.78. due to reduction of mezzanine area in Unit 101.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.