Commercial / Multi / Industrial · BP130541
Certified Professional Building Permit Process - Phase 2: Complete remainder of building floors 4 through to 10 for occupancy New construction of a 10 storey student residential housing building. Building Classification Group C 3.2.2.48-EMTC with Group C and Group A2 major occupancies and with subsidiary Group D, Group F-2 and Group F-3 occupancies. Building area 1059.58 m2. Sprinklered with Fire alarm system. Key FRR/FS: 2Hr non-combustible at stair/elev/shaft and other spaces, 2hr non-combustible floor at levels 1-4. 2hr EMTC at floor levels 5 -10. 1hr at bedroom suites and corridors. Total GFA = 10,035.77m2. Alternative Solutions for: Interconnected floors at level 2 and 3, Exit exposure protection at NW stair, Cafeteria exit and stair 3 exit path, Use of EMTC construction, Combustible piping at geo-exchange energy system, Omission of smoke dampers at residential floors, Slab by-pass curtain wall panel and Combustible exterior soffit on level 3.
Other addresses listed in this application: 900 FIFTH STREET.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.