Commercial / Multi-Res Alteration · BP131746
Life safety upgrades to various units. Add exit corridor to Unit 102; legalize minor partition alterations in Units 202, 205, and 206; Add fire rated door and partitions in Unit 203 exit; combine 204A and 204B into new Unit 204 and add fire rated door and partitions in exit; Unit 102: Group E; Units 202-206: Group D. Existing Building Classifications (BP017975 and BP018807, see events), separated by 4-hr firewall at GL 4: BLDG A (GL 1-4): NBC 1977 3.2.2.30/.34/.42, Group D/E/F2, 1963 m2 building area, two storeys, facing one street, sprinklered, with fire alarm. Combustible construction, 45-min FRR/FS floors, 45-min FRR mezzanines, 45-min FRR or NC roofs, 45-min FRR or NC loadbearing assemblies. BLDG B (GL 4-8): NBC 1980 3.2.2.14/.29/.33, Group A2/D/E, 1351 m2 building area, two storeys, facing two streets, sprinklered, with fire alarm. Combustible construction, 45-min FRR/FS floors, 45-min FRR mezzanines, 45-min FRR or NC roofs, 45-min FRR or NC loadbearing assemblies.
Other addresses listed in this application: 2520 BOWEN ROAD.
Source: City of Nanaimo — Planning, building, demolition and subdivision records.