Residential Building Permit · BPRES-2021-10994
The objective of this project is make an Addition to enlarge two ground floor rooms. This will enable the use of the present Den (former bedroom) as the Master Bedroom, which will allow us to stay in this house when we can no longer safely navigate the stairs to the upper level. The former Dining Room would become the new Den. The existing structure has 3 bedrooms, bathroom and walk-in attic on the upper floor. The ground floor has living room, dining room, den (former bedroom), kitchen, bathroom and entry room. The basement is concrete foundation walls and floor. The Addition will extend the den (former bedroom) and the dining room an extra 8 feet at the rear of the house. This will be a single level addition to join to the existing structure on two sides. The 28' side would join the Den & Dining rooms while the 8' side would join the 8' end of the existing Entry Room (which is 8' x 12'). The Addition would then match the roof profile of the existing Entry Room. The 28' side of the Addition would match the back wall of the existing back of the house. Instead of a full foundation the plan is to have 4 sonotube supports anchored to concrete pads below 4' depth. The floor will be fully insulated and the area below will be adequately protected from weather and pests. The current forced air heating system will have outlets directly adjacent to the juncture of the existing structure and the Addition, so no additional heating should be necessary (i.e. no ductwork under the crawlspace). There will be minimal requirement for electrical work which is expected to require the relocation of two electric outlets and perhaps the installation of two to four new ones in the Addition. No plumbing will be required. To answer questions returned; -the exterior will be finished with cedar shingles. -there are to be no exterior doors; as shown in the plans submitted, access to the Addition will be from the existing rooms that are being enlarged. Carry beams of three 2x8's will be used at Work Type: Addition. Primary Work Scope: Addition. Type Of Structure: Dwelling - Single Detached. Estimated Project Value: 17000. Existing Residential Units: 1. Total End Residential Units: 1. Net New Units: 0. Building Footprint Area: 20.8. Number Of Storeys: 1. Overall Building Height: 3.43. Pid: 00646992.
Source: Halifax — Building permits. Source: Halifax Regional Municipality open municipal data. Adapted for FolioProjects; no municipal endorsement implied.
Comments
New comments are public while this project is public. Earlier members-only comments remain restricted.
Sign in to comment.
No comments on this page.